Difficulty
Easy
Steps
4
Time Required
5 minutes
Sections
2
- Front Panel
- 3 steps
- Range/Hold Buttons
- 1 step
Flags
0
BackFluke 77 Series III
Full Screen
Options
History
Save to Favorites
Download PDF
Edit
Translate
Get Shareable Link
Embed This Guide
Notify Me of Changes
Stop Notifications
Introduction
What you need
Step 1
Front Panel
- Be sure any test leads are out and the multimeter is off before opening the device.
- Turn the multimeter so it is display side down.
- Lift up the back stand of the device by putting your thumb in the curved well at the bottom of the device, so you have access to the two covered screws below.
Be sure any test leads are out and the multimeter is off before opening the device.
Turn the multimeter so it is display side down.
Lift up the back stand of the device by putting your thumb in the curved well at the bottom of the device, so you have access to the two covered screws below.
1024
Step 2
- Use your Phillips #2 Screwdriver to remove the four black 21 mm Phillips #2 screws.
Use your Phillips #2 Screwdriver to remove the four black 21 mm Phillips #2 screws.
Step 3
- Turn the Fluke 77 Series III Multimeter back over so that it is display side up.
- Pry the front panel from the back panel at the seam.
- If the front panel does not come off easily, move a plastic opening tool along the seam until the panels separate completely.
Turn the Fluke 77 Series III Multimeter back over so that it is display side up.
Pry the front panel from the back panel at the seam.
If the front panel does not come off easily, move a plastic opening tool along the seam until the panels separate completely.
Step 4
Range/Hold Buttons
- Locate the rubber range and hold buttons in the internal assembly. These are found just below the LCD screen on the left hand side.
- The buttons are attached so they will come out of the multimeter as a single part.
- Remove the rubber range and hold button part with your thumb and forefinger.
Locate the rubber range and hold buttons in the internal assembly. These are found just below the LCD screen on the left hand side.
The buttons are attached so they will come out of the multimeter as a single part.
Remove the rubber range and hold button part with your thumb and forefinger.
To reassemble your device, follow these instructions in reverse order.
Cancel: I did not complete this guide.
One other person completed this guide.