  • Front Panel
  • 3 steps
  • Battery
  • 2 steps

Flags

0

  • BackFluke 77 Series III

  • Full Screen

  • Options

  • History

  • Save to Favorites

  • Download PDF

  • Edit

  • Translate

  • Get Shareable Link

  • Embed This Guide

  • Notify Me of Changes

  • Stop Notifications

Introduction

What you need

Step 1

              Front Panel               
  • Be sure any test leads are out and the multimeter is off before opening the device.
  • Turn the multimeter so it is display side down.
  • Lift up the back stand of the device by putting your thumb in the curved well at the bottom of the device, so you have access to the two covered screws below.

Be sure any test leads are out and the multimeter is off before opening the device.

Turn the multimeter so it is display side down.

Lift up the back stand of the device by putting your thumb in the curved well at the bottom of the device, so you have access to the two covered screws below.

1024

Step 2

  • Use your Phillips #2 Screwdriver to remove the four black 21 mm Phillips #2 screws.

Use your Phillips #2 Screwdriver to remove the four black 21 mm Phillips #2 screws.

Step 3

  • Turn the Fluke 77 Series III Multimeter back over so that it is display side up.
  • Pry the front panel from the back panel at the seam.
  • If the front panel does not come off easily, move a plastic opening tool along the seam until the panels separate completely.

Turn the Fluke 77 Series III Multimeter back over so that it is display side up.

Pry the front panel from the back panel at the seam.

If the front panel does not come off easily, move a plastic opening tool along the seam until the panels separate completely.

Step 4

              Battery               
  • When doing this next step, make sure to remove the battery slowly, so you don’t damage the wires connecting the battery to the device.
  • Locate the 9V battery in the lower right corner of the device.
  • Pull the battery out of its terminal.

When doing this next step, make sure to remove the battery slowly, so you don’t damage the wires connecting the battery to the device.

Locate the 9V battery in the lower right corner of the device.

Pull the battery out of its terminal.

Step 5

  • Only pull on the metal snaps and battery. Pulling the cords may damage them.
  • Detach the two metal snaps from the battery.

Only pull on the metal snaps and battery. Pulling the cords may damage them.

Detach the two metal snaps from the battery.

To reassemble your device, follow these instructions in reverse order.

Cancel: I did not complete this guide.

                                                                                      5 other people completed this guide.                                             

Author

                                      with 4 other contributors 

                    Jessica Bombardier Shaw                     

Member since: 01/29/2014

1,006 Reputation

                                      7 Guides authored                  



                       Badges:
                       13







                                                        +10 more badges                           

Team

                       Cal Poly, Team 2-10, Amido Winter 2014                        

                                                  Member of Cal Poly, Team 2-10, Amido Winter 2014 



                    CPSU-AMIDO-W14S2G10                     


                                            4 Members                     


                                            10 Guides authored                     

petruskewichw - Dec 12, 2015

Reply

Easy to understand and all went well!