Difficulty
Easy
Steps
6
Time Required
5 minutes
Sections
3
- Guide Spring
- 1 step
- Auto-Feeder Disengagement
- 3 steps
- Auto-Feeder
- 2 steps
Flags
0
BackElectric Eel Drain Cleaner Z5K-1/2IC75-AF (2013)
Full Screen
Options
History
Save to Favorites
Download PDF
Edit
Translate
Get Shareable Link
Embed This Guide
Notify Me of Changes
Stop Notifications
Introduction
What you need
Step 1
Remove the Guide Spring
- Unplug your drain cleaner before starting this guide. Because this device may have been used in a septic setting, it should be cleaned and disinfected as much as possible before disassembly.
- Wear gloves to protect your hands from injury when handling the cable.
- Ensure the cable is completely retracted into the auto-feeder.
- Twist the guide spring counter-clockwise to unscrew it from the auto-feeder.
- Remove the guide spring.
Unplug your drain cleaner before starting this guide. Because this device may have been used in a septic setting, it should be cleaned and disinfected as much as possible before disassembly.
Wear gloves to protect your hands from injury when handling the cable.
Ensure the cable is completely retracted into the auto-feeder.
Twist the guide spring counter-clockwise to unscrew it from the auto-feeder.
Remove the guide spring.
1024
Step 2
Release the Tension Spring
- Unscrew the tension knob to loosen the tension spring in the top feeder assembly.
Unscrew the tension knob to loosen the tension spring in the top feeder assembly.
Step 3
Set the Feeder in Neutral Position
- Set the feeder adjustment knob in the neutral position, in between the “FWD” and “REV” positions.
Set the feeder adjustment knob in the neutral position, in between the “FWD” and “REV” positions.
Step 4
Disengage the Top Bearing
- Push the top control finger up as far as possible.
- This disengages the top feeder assembly and allows the cable to freely move through the feeder. The finger may fall back down on its own and restrict cable movement. If this occurs, simply push the finger back up.
Push the top control finger up as far as possible.
This disengages the top feeder assembly and allows the cable to freely move through the feeder. The finger may fall back down on its own and restrict cable movement. If this occurs, simply push the finger back up.
Step 5
Remove the Auto-Feeder
- Use a 1/2" open-ended wrench to remove the two bolts from the bottom of the feeder body mounting arm.
Use a 1/2" open-ended wrench to remove the two bolts from the bottom of the feeder body mounting arm.
Step 6
- Remove the auto-feeder from the cable.
- If the end of the cable won’t pass through the feeder, ensure that the top bearing is completely disengaged as described in step 4 of this guide.
Remove the auto-feeder from the cable.
If the end of the cable won’t pass through the feeder, ensure that the top bearing is completely disengaged as described in step 4 of this guide.
To reassemble your device, follow these instructions in reverse order.