Difficulty

Easy

Steps

6

Time Required

                          5 minutes            

Sections

3

  • Guide Spring
  • 1 step
  • Auto-Feeder Disengagement
  • 3 steps
  • Auto-Feeder
  • 2 steps

Flags

0

  • BackElectric Eel Drain Cleaner Z5K-1/2IC75-AF (2013)

  • Full Screen

  • Options

  • History

  • Save to Favorites

  • Download PDF

  • Edit

  • Translate

  • Get Shareable Link

  • Embed This Guide

  • Notify Me of Changes

  • Stop Notifications

Introduction

What you need

Step 1

              Remove the Guide Spring               
  • Unplug your drain cleaner before starting this guide. Because this device may have been used in a septic setting, it should be cleaned and disinfected as much as possible before disassembly.
  • Wear gloves to protect your hands from injury when handling the cable.
  • Ensure the cable is completely retracted into the auto-feeder.
  • Twist the guide spring counter-clockwise to unscrew it from the auto-feeder.
  • Remove the guide spring.

Unplug your drain cleaner before starting this guide. Because this device may have been used in a septic setting, it should be cleaned and disinfected as much as possible before disassembly.

Wear gloves to protect your hands from injury when handling the cable.

Ensure the cable is completely retracted into the auto-feeder.

Twist the guide spring counter-clockwise to unscrew it from the auto-feeder.

Remove the guide spring.

1024

Step 2

              Release the Tension Spring               
  • Unscrew the tension knob to loosen the tension spring in the top feeder assembly.

Unscrew the tension knob to loosen the tension spring in the top feeder assembly.

Step 3

              Set the Feeder in Neutral Position               
  • Set the feeder adjustment knob in the neutral position, in between the “FWD” and “REV” positions.

Set the feeder adjustment knob in the neutral position, in between the “FWD” and “REV” positions.

Step 4

              Disengage the Top Bearing               
  • Push the top control finger up as far as possible.
  • This disengages the top feeder assembly and allows the cable to freely move through the feeder. The finger may fall back down on its own and restrict cable movement. If this occurs, simply push the finger back up.

Push the top control finger up as far as possible.

This disengages the top feeder assembly and allows the cable to freely move through the feeder. The finger may fall back down on its own and restrict cable movement. If this occurs, simply push the finger back up.

Step 5

              Remove the Auto-Feeder               
  • Use a 1/2" open-ended wrench to remove the two bolts from the bottom of the feeder body mounting arm.

Use a 1/2" open-ended wrench to remove the two bolts from the bottom of the feeder body mounting arm.

Step 6

  • Remove the auto-feeder from the cable.
  • If the end of the cable won’t pass through the feeder, ensure that the top bearing is completely disengaged as described in step 4 of this guide.

Remove the auto-feeder from the cable.

If the end of the cable won’t pass through the feeder, ensure that the top bearing is completely disengaged as described in step 4 of this guide.

To reassemble your device, follow these instructions in reverse order.

Cancel: I did not complete this guide.

                                                                                      One other person completed this guide.                                             

Author

                                      with 1 other contributor 

                    Tarun Thiruma                     

Member since: 11/20/2019

31,630 Reputation

                                      133 Guides authored                  



                       Badges:
                       32