Difficulty
Easy
Steps
9
Time Required
20 minutes
Sections
1
- EK3211 Kitchen Scale Disassembly
- 9 steps
Flags
2
In Progress
This guide is a work in progress. Reload periodically to see the latest changes!
Member-Contributed Guide
An awesome member of our community made this guide. It is not managed by iFixit staff.
BackEK3211 Kitchen Scale
Full Screen
Options
History
Save to Favorites
Download PDF
Edit
Translate
Get Shareable Link
Embed This Guide
Notify Me of Changes
Stop Notifications
What you need
Step 1
Remove label to access screws
- Peel back the “ELECTRONIC KITCHEN SCALE” label to reveal two screws underneath.
Peel back the “ELECTRONIC KITCHEN SCALE” label to reveal two screws underneath.
1024
Step 2
- Use a #2 Phillips screwdriver to remove the two screws.
- These screws are very tight and prone to strip.
Use a #2 Phillips screwdriver to remove the two screws.
These screws are very tight and prone to strip.
Step 3
- Remove the four screws holding the top veneer panel to the base.
Remove the four screws holding the top veneer panel to the base.
Step 4
- Remove the top veneer panel. It should come off without any force.
- There are two small plastic clips on the edge below the screen, which must be inserted correctly during reassembly.
Remove the top veneer panel. It should come off without any force.
There are two small plastic clips on the edge below the screen, which must be inserted correctly during reassembly.
Step 5
- Remove the screw holding the PCB and screen in place using a #1 Phillips screwdriver.
Remove the screw holding the PCB and screen in place using a #1 Phillips screwdriver.
Step 6
- Remove the PCB and screen assembly.
- The buttons should also lift up with the rest of the PCB/screen assembly.
Remove the PCB and screen assembly.
The buttons should also lift up with the rest of the PCB/screen assembly.
Step 7
- Use a #1 Phillips screwdriver to remove the four screws holding the load cell mount to the base.
Use a #1 Phillips screwdriver to remove the four screws holding the load cell mount to the base.
Step 8
- Remove the two screws holding the load cell to the bracket using a #2 Phillips screwdriver.
Remove the two screws holding the load cell to the bracket using a #2 Phillips screwdriver.
Step 9
- Separate the bracket from the load cell.
- Be careful not to lose the spacer plate.
Separate the bracket from the load cell.
Be careful not to lose the spacer plate.
To reassemble your device, follow these instructions in reverse order.