Introduction

The display remained black.

So I had to find a way to disassemble.

Extra rausholen the Heißluftföhn and time consuming to heat the glass plate? It would have to be easier!

What you need

Step 1

              Open the balance               
  • Since it is not important in the balance to get the adhesive surfaces take a beveled spatula. It’s much easier and faster.

Since it is not important in the balance to get the adhesive surfaces take a beveled spatula. It’s much easier and faster.

1024

Step 2

  • Contrary to the other instructions, the board is located directly on the plastic housing. Through the 3 holes water gets into the balance and through the adhesion it spreads over the complete underside of the board
  • The Libra continues to change. Only this time too much water had penetrated which had spread under the board.
  • Clean the underside of the board with acetone. Alternatively, isopropanol.
  • After the board was dry, the scales spoke to me again. And so that water does not penetrate again, I taped the holes with silicone
  • Finally, glue the round cap to the glass plate with a little silicone glue. Because even if the board has a silicone protective coating, it would not be good if Wassser came from above on the SMD components.

Contrary to the other instructions, the board is located directly on the plastic housing. Through the 3 holes water gets into the balance and through the adhesion it spreads over the complete underside of the board

The Libra continues to change. Only this time too much water had penetrated which had spread under the board.

Clean the underside of the board with acetone. Alternatively, isopropanol.

After the board was dry, the scales spoke to me again. And so that water does not penetrate again, I taped the holes with silicone

Finally, glue the round cap to the glass plate with a little silicone glue. Because even if the board has a silicone protective coating, it would not be good if Wassser came from above on the SMD components.

Repeat the steps in order to reassemble your device.

Cancel: I did not complete this guide.

                                                                                      One other person completed this guide.                                             


        These translators are helping us fix the world!      Want to contribute?      Start translating › 

Special thanks to these translators:

100%

Israel

irlanda

Author

                                      with 1 other contributor 

                    Marina                     

Member since: 10/12/2017

115 Reputation

                                      1 Guide authored                  



                       Badges:
                       3

David Hopkins - Jan 1, 2023

Reply

this does not tell you how to open it, only to use a spatula. this is not a guide, it is a waste of time.