Introduction
What you need
Step 1
Before and after cleaning.
- Translucent cover before and after cleaning.
Translucent cover before and after cleaning.
1024
Step 2
Removing rotating brush and red lid.
- Remove red lid by releasing the clamps (yellow arrows) with a spudger to get access to more screws, that hold the translucent shield.
- Remove Two Torx screws that hold the silver cover-plate on the opposite side of the motorhead that covers the translucent shield.
- Remove the rotating brush by realeasing it with a coin.
Remove red lid by releasing the clamps (yellow arrows) with a spudger to get access to more screws, that hold the translucent shield.
Remove Two Torx screws that hold the silver cover-plate on the opposite side of the motorhead that covers the translucent shield.
Remove the rotating brush by realeasing it with a coin.
Step 3
Removing screws, that hold the silver and the translucent shield.
- Remove the five Torx screws (red), that hold the translucent shield.
- Remove the single shorter Torx screw (yellow), that fixes the silver and the translucent shield.
Remove the five Torx screws (red), that hold the translucent shield.
Remove the single shorter Torx screw (yellow), that fixes the silver and the translucent shield.
Step 4
Removing the silver shield.
- Remove the silver shield by gently pulling into the directions of the red arrows. (This is the only tricky part of the whole procedure.)
Remove the silver shield by gently pulling into the directions of the red arrows. (This is the only tricky part of the whole procedure.)
Step 5
Removing the translucent shield.
- After removal of the silver-shield the translucent shield can be removed easily. The black and white cables are attached with the black plug and can be reattached easily on reassambly.
After removal of the silver-shield the translucent shield can be removed easily. The black and white cables are attached with the black plug and can be reattached easily on reassambly.
Step 6
Ready for spring-cleaning.
- After removal of the translucent shield, both the shield and the silver-skeleton that holds the rotating motorhead can be cleaned thoroughly.
After removal of the translucent shield, both the shield and the silver-skeleton that holds the rotating motorhead can be cleaned thoroughly.
To reassemble your device, follow these instructions in reverse order.