Introduction

What you need

Step 1

              Electrical Cord               
  • Press the red button on the back to release the hose and allow for easy access to the back

Press the red button on the back to release the hose and allow for easy access to the back

1024

Step 2

  • Remove the four 15 mm T-10 black screws now showing in the back of the vacuum hose track, using the Phillips 0 screwdriver found in the iFixit tool kit.

Remove the four 15 mm T-10 black screws now showing in the back of the vacuum hose track, using the Phillips 0 screwdriver found in the iFixit tool kit.

Step 3

  • Use a pair of needle nosed pliers to press both tabs simultaneously.
  • Hold onto the front hatch while doing this or it will fall off and a spring and lever will fall out with it.
  • Remove the hatch carefully exposing the wiring underneath

Use a pair of needle nosed pliers to press both tabs simultaneously.

Hold onto the front hatch while doing this or it will fall off and a spring and lever will fall out with it.

Remove the hatch carefully exposing the wiring underneath

Step 4

  • Remove the black wire from its connection near the top of the hatch

Remove the black wire from its connection near the top of the hatch

Step 5

  • Open the black box near the bottom of the hatch area using the two push tabs
  • This exposes the white wire’s connection

Open the black box near the bottom of the hatch area using the two push tabs

This exposes the white wire’s connection

Step 6

  • Disconnect the white wire using the small metal tab.
  • Do not damage the wire during the process.

Disconnect the white wire using the small metal tab.

Do not damage the wire during the process.

Step 7

  • Pull vertically on the grey cord now and it should separate from the rest of the vacuum
  • To replace the cord, slide the new grey cord into place and connect the two wires again then complete the steps in reverse

Pull vertically on the grey cord now and it should separate from the rest of the vacuum

To replace the cord, slide the new grey cord into place and connect the two wires again then complete the steps in reverse

To reassemble your device, follow these instructions in reverse order.

Cancel: I did not complete this guide.

                                                                                      One other person completed this guide.                                             

Author

                                      with 3 other contributors 

                    Nicole Abraham                     

Member since: 01/26/2017

821 Reputation

                                      5 Guides authored                  



                       Badges:
                       10







                                                        +7 more badges                           

Team

                       Cal Poly, Team 21-2, Maness Winter 2017                        

                                                  Member of Cal Poly, Team 21-2, Maness Winter 2017 



                    CPSU-MANESS-W17S21G2                     


                                            4 Members                     


                                            10 Guides authored                     

Jordan Adams - Feb 26, 2018

Reply

Supposing that one doesn’t hold onto the front part, and the spring and lever fall out, how does one replace said spring and lever?