Introduction
What you need
Step 1
Electrical Cord
- Press the red button on the back to release the hose and allow for easy access to the back
Press the red button on the back to release the hose and allow for easy access to the back
1024
Step 2
- Remove the four 15 mm T-10 black screws now showing in the back of the vacuum hose track, using the Phillips 0 screwdriver found in the iFixit tool kit.
Remove the four 15 mm T-10 black screws now showing in the back of the vacuum hose track, using the Phillips 0 screwdriver found in the iFixit tool kit.
Step 3
- Use a pair of needle nosed pliers to press both tabs simultaneously.
- Hold onto the front hatch while doing this or it will fall off and a spring and lever will fall out with it.
- Remove the hatch carefully exposing the wiring underneath
Use a pair of needle nosed pliers to press both tabs simultaneously.
Hold onto the front hatch while doing this or it will fall off and a spring and lever will fall out with it.
Remove the hatch carefully exposing the wiring underneath
Step 4
- Remove the black wire from its connection near the top of the hatch
Remove the black wire from its connection near the top of the hatch
Step 5
- Open the black box near the bottom of the hatch area using the two push tabs
- This exposes the white wire’s connection
Open the black box near the bottom of the hatch area using the two push tabs
This exposes the white wire’s connection
Step 6
- Disconnect the white wire using the small metal tab.
- Do not damage the wire during the process.
Disconnect the white wire using the small metal tab.
Do not damage the wire during the process.
Step 7
- Pull vertically on the grey cord now and it should separate from the rest of the vacuum
- To replace the cord, slide the new grey cord into place and connect the two wires again then complete the steps in reverse
Pull vertically on the grey cord now and it should separate from the rest of the vacuum
To replace the cord, slide the new grey cord into place and connect the two wires again then complete the steps in reverse
To reassemble your device, follow these instructions in reverse order.
Cancel: I did not complete this guide.
One other person completed this guide.
Author
with 3 other contributors
Nicole Abraham
Member since: 01/26/2017
821 Reputation
5 Guides authored
Badges:
10
+7 more badges
Team
Cal Poly, Team 21-2, Maness Winter 2017
Member of Cal Poly, Team 21-2, Maness Winter 2017
CPSU-MANESS-W17S21G2
4 Members
10 Guides authored
Jordan Adams - Feb 26, 2018
Reply
Supposing that one doesn’t hold onto the front part, and the spring and lever fall out, how does one replace said spring and lever?