Difficulty

Moderate

Steps

8

Time Required

Suggest a time??

Sections

3

  • DeLonghi ECAM back panel removal
  • 2 steps
  • DeLonghi ECAM Series left side panel
  • 1 step
  • Pump
  • 5 steps

Flags

1

Member-Contributed Guide

An awesome member of our community made this guide. It is not managed by iFixit staff.

  • BackDeLonghi ECAM Series

  • Full Screen

  • Options

  • History

  • Save to Favorites

  • Download PDF

  • Translate

  • Get Shareable Link

  • Embed This Guide

  • Notify Me of Changes

  • Stop Notifications

Introduction

What you need

Step 1

              DeLonghi ECAM back panel removal               
  • Unplug the power cord!
  • Remove all attachments such as water tank, pulp drawer, brew group.
  • Turn the machine with the back facing you.
  • Remove five Torx T20 security screws.
  • A small hurdle: These screws have a pin in the middle, so the screwdriver must have a hole.

Unplug the power cord!

Remove all attachments such as water tank, pulp drawer, brew group.

Turn the machine with the back facing you.

Remove five Torx T20 security screws.

A small hurdle: These screws have a pin in the middle, so the screwdriver must have a hole.

1024

Step 2

  • Lift out the back.
  • The following components are immediately visible:
  • grinder
  • pump
  • flowmeter

Lift out the back.

The following components are immediately visible:

grinder

pump

flowmeter

Step 3

              DeLonghi ECAM Series left side panel               
  • Push the side panel back about 1.5 cm.
  • Lift off the panel.
  • The following compononents are exposed:
  • Heater
  • Expansion chamber
  • Gear drive
  • Steam valve

Push the side panel back about 1.5 cm.

Lift off the panel.

The following compononents are exposed:

Heater

Expansion chamber

Gear drive

Steam valve

Step 4

              Pump               
  • The pump is located on the back of the device. It is supported by a spring and a rubber surround.

The pump is located on the back of the device. It is supported by a spring and a rubber surround.

Step 5

  • Pull out the metal clip at the outlet of the mebrand damper.
  • Pull off the pressure hose. There is an O-ring at the end of the hose, which is usually stuck in the connection. Replace it during reassembly.

Pull out the metal clip at the outlet of the mebrand damper.

Pull off the pressure hose. There is an O-ring at the end of the hose, which is usually stuck in the connection. Replace it during reassembly.

Step 6

  • Pull the pump out to the rear.
  • Unscrew the diaphragm damper counterclockwise.

Pull the pump out to the rear.

Unscrew the diaphragm damper counterclockwise.

Step 7

  • Disconnect the two flat connectors and the thermal protection switch.

Disconnect the two flat connectors and the thermal protection switch.

Step 8

  • Detach the silicone hose on the left side and pull out the pump completely.
  • Remove the spring and the hose on the left side.
  • Detach the rubber holder.

Detach the silicone hose on the left side and pull out the pump completely.

Remove the spring and the hose on the left side.

Detach the rubber holder.

Work through the steps in reverse order to reassemble your device.

Cancel: I did not complete this guide.