Introduction

What you need

Step 1

              DeLonghi ECAM back panel removal               
  • Unplug the power cord!
  • Remove all attachments such as water tank, pulp drawer, brew group.
  • Turn the machine with the back facing you.
  • Remove five Torx T20 security screws.
  • A small hurdle: These screws have a pin in the middle, so the screwdriver must have a hole.

Unplug the power cord!

Remove all attachments such as water tank, pulp drawer, brew group.

Turn the machine with the back facing you.

Remove five Torx T20 security screws.

A small hurdle: These screws have a pin in the middle, so the screwdriver must have a hole.

1024

Step 2

  • Lift out the back.
  • The following components are immediately visible:
  • grinder
  • pump
  • flowmeter

Lift out the back.

The following components are immediately visible:

grinder

pump

flowmeter

Step 3

              Replace power board               
  • Also slide the cover - if not already done - on the water tank side backwards and remove it.

Also slide the cover - if not already done - on the water tank side backwards and remove it.

Step 4

  • The power board is located under the cover. It is fixed with four screws in the corners and connected with a lot of cables.
  • Move the cables a bit to the side and unscrew the four Phillips screws in the corners.

The power board is located under the cover. It is fixed with four screws in the corners and connected with a lot of cables.

Move the cables a bit to the side and unscrew the four Phillips screws in the corners.

Step 5

  • The cables have many different connectors and can almost not be confused. Make a special note of where the flat connectors are connected.
  • The flat connectors can be disconnected more easily if you lift the cover in the corner of the device to the side.
  • Lift the board out a few centimeters.
  • Carefully loosen all connections. Some are secured with latches that you have to push away first.

The cables have many different connectors and can almost not be confused. Make a special note of where the flat connectors are connected.

The flat connectors can be disconnected more easily if you lift the cover in the corner of the device to the side.

Lift the board out a few centimeters.

Carefully loosen all connections. Some are secured with latches that you have to push away first.

Work through the steps in reverse order to reassemble your device.

Cancel: I did not complete this guide.

                                                                                      One other person completed this guide.                                             


        oldturkey03 is helping us fix the world!      Want to contribute?      Start translating › 

Special thanks to these translators:

100%

oldturkey03

Author

                                      with 1 other contributor 

                    VauWeh                     

Member since: 10/19/2015

160,518 Reputation

                                      211 Guides authored                  



                       Badges:
                       41







                                                        +38 more badges