Difficulty
Moderate
Steps
8
Time Required
Suggest a time??
Sections
1
- Brewing Group Seal Replacement
- 8 steps
Flags
Member-Contributed Guide
An awesome member of our community made this guide. It is not managed by iFixit staff.
BackDeLonghi ECAM Series
Full Screen
Options
History
Save to Favorites
Download PDF
Translate
Get Shareable Link
Embed This Guide
Notify Me of Changes
Stop Notifications
Introduction
What you need
Step 1
Brewing Group Seal Replacement
- Switch off the machine so that the brew group moves to the removal position.
- Unplug the power cord.
- Take out the water tank and the pulp bowl.
- Open the hatch behind the water tank.
- Press the two red buttons together and pull out the brew group.
Switch off the machine so that the brew group moves to the removal position.
Unplug the power cord.
Take out the water tank and the pulp bowl.
Open the hatch behind the water tank.
Press the two red buttons together and pull out the brew group.
1024
Step 2
- Lay the device on its side so that you can easily access the upper brewing plunger.
- Unscrew the two Phillips screws.
- Remove the black plastic cap from the top brew plunger, remembering the orientation for later reassembly.
- Clean everything under the cap and the cap itself.
- Lightly grease the new O-ring with food grade silicone grease and replace the top O-ring.
- Screw the cap back on.
Lay the device on its side so that you can easily access the upper brewing plunger.
Unscrew the two Phillips screws.
Remove the black plastic cap from the top brew plunger, remembering the orientation for later reassembly.
Clean everything under the cap and the cap itself.
Lightly grease the new O-ring with food grade silicone grease and replace the top O-ring.
Screw the cap back on.
Step 3
- Unscrew two Phillips screws on the front and back of the brew group.
Unscrew two Phillips screws on the front and back of the brew group.
Step 4
- Now carefully separate the front and back.
- The pomace shovel at the top is under tension from a torsion spring, pay attention to this when removing it.
- When assembling, you first have to insert the spring of the shovel, then place the shovel wide open on it and then swivel it in. Only then can the two halves be pressed together again.
- Note the position of the two levers with the teeth in the lower area and the position of the piston for later assembly. Then pull them off.
Now carefully separate the front and back.
The pomace shovel at the top is under tension from a torsion spring, pay attention to this when removing it.
When assembling, you first have to insert the spring of the shovel, then place the shovel wide open on it and then swivel it in. Only then can the two halves be pressed together again.
Note the position of the two levers with the teeth in the lower area and the position of the piston for later assembly. Then pull them off.
Step 5
- Push the plunger up and out.
- Remove the old O-rings.
Push the plunger up and out.
Remove the old O-rings.
Step 6
- Unscrew the Phillips screw on the brewing sieve.
- Take off the brew sieve.
Unscrew the Phillips screw on the brewing sieve.
Take off the brew sieve.
Step 7
- The crema valve is located in the bottom of the flask under a plastic cap. You should also take this opportunity to inspect and clean it.
- The cap is very tight and difficult to remove.
- Pry the cap out with a sharp tool. Alternately apply the tool to the nubs. You need a lot of patience.
- Take out the parts of the crema valve.
- Thoroughly clean all parts of the brew group. Install two new O-rings on the piston.
- Lightly grease the O-rings and the axles of the moving parts with food grade silicone grease.
The crema valve is located in the bottom of the flask under a plastic cap. You should also take this opportunity to inspect and clean it.
The cap is very tight and difficult to remove.
Pry the cap out with a sharp tool. Alternately apply the tool to the nubs. You need a lot of patience.
Take out the parts of the crema valve.
Thoroughly clean all parts of the brew group. Install two new O-rings on the piston.
Lightly grease the O-rings and the axles of the moving parts with food grade silicone grease.
Step 8
- Insert instructions here.
Insert instructions here.
Work through the steps in reverse order to reassemble your device.
Cancel: I did not complete this guide.
These translators are helping us fix the world! Want to contribute? Start translating ›
Special thanks to these translators:
100%
oldturkey03
shingle
Annika Faelker
Author
with 2 other contributors
VauWeh
Member since: 10/19/2015
160,518 Reputation
211 Guides authored
Badges:
41
+38 more badges
Lisa W - Jun 7, 2022
Reply
Step 8- Is this to show the orientation of the plunger? No instructions here. Also, there is a small rubber fitting somewhere inside when the halves are taken apart. This is not shown or noted.
VauWeh - Jun 7, 2022
Reply
You are right. Someone put the picture and no notes with it. Presumably to recognize the position. The rubber part (triangle shaped?) is a a stop for the shovel. It is clamped between the two halves of the housing.