Difficulty
Easy
Steps
7
Time Required
5 minutes
Sections
2
- Mainboard
- 5 steps
- Battery
- 2 steps
Flags
0
BackCen-Tech Digital Multimeter
Full Screen
Options
History
Save to Favorites
Download PDF
Edit
Translate
Get Shareable Link
Embed This Guide
Notify Me of Changes
Stop Notifications
Introduction
What you need
Step 1
Position Device
- Place the meter face down, and the back panel and screws can be seen.
Place the meter face down, and the back panel and screws can be seen.
1024
Step 2
Remove Back Panel Screws
- Unscrew the two 9mm screws on the back panel using a #0 Phillips screwdriver.
Unscrew the two 9mm screws on the back panel using a #0 Phillips screwdriver.
Step 3
Remove Back Panel
- Remove the back panel of the device by lifting upward.
- Remove the battery from the meter before continuing.
Remove the back panel of the device by lifting upward.
Remove the battery from the meter before continuing.
Step 4
Unscrew Motherboard
- Remove the four 7mm Phillips screws holding the circuit board in place.
Remove the four 7mm Phillips screws holding the circuit board in place.
Step 5
Remove Motherboard
- Gently lift the circuit board away from the device casing.
- Remove the battery after removing the back cover to reduce the chances of short-circuiting the circuit board.
Gently lift the circuit board away from the device casing.
Remove the battery after removing the back cover to reduce the chances of short-circuiting the circuit board.
Step 6
Locate Battery Attachment
- After removing the outer casing and motherboard of the device, locate the attachment site of the battery to the motherboard.
After removing the outer casing and motherboard of the device, locate the attachment site of the battery to the motherboard.
Step 7
Remove Battery
- Unsnap the battery from its attachment plate.
- When replacing the battery with a new one, be sure to properly align battery heads (positive and negative) with snaps. The positive battery head should be connected to the negative wire, and vice versa.
Unsnap the battery from its attachment plate.
When replacing the battery with a new one, be sure to properly align battery heads (positive and negative) with snaps. The positive battery head should be connected to the negative wire, and vice versa.
To reassemble your device, follow these instructions in reverse order.
Cancel: I did not complete this guide.
4 other people completed this guide.
Author
with 3 other contributors
Anna Kihm
Member since: 10/13/2014
918 Reputation
5 Guides authored
Badges:
23
+20 more badges
Team
Clemson, Team 2-4, Benson Fall 2014
Member of Clemson, Team 2-4, Benson Fall 2014
CLEM-BENSON-F14S2G4
4 Members
6 Guides authored
Osman Vincent - Jan 27, 2019
Reply
My case was glued or welded together. I thought it was going to break elsewhere first
No need to remove the board. Just use a screwdriver to pop the battery connector off
dan - Dec 4, 2022
Reply
In at least some of these meters, the caution label has been applied upside-down, so that it covers the screw holes.
The top of the panel has two tabs engaged (can be seen by carefully examining photos above). After screws are freed, lift the bottom edge first to allow tabs to disengage. Also, routing of battery clip wires is critical; take care that they clear the case edges.